Re: [doc] Re: thermo time switch part numbers
[Date Prev][Date Next][Thread Prev][Thread Next][Date Index][Thread Index]
Re: [doc] Re: thermo time switch part numbers
- From: Martin Gutkowski <martin@xxxxxxxxxxxxxx>
- Date: Mon, 12 Sep 2005 18:23:09 +0100
The original is actually a VDO part but the connector is prone to
breaking. The plug on the loom can be forced into the bosch plug
Martin
Mike Bosworth wrote:
> Hi Steve
>
> Its a Bosch 0280 130 214 ( DMC Part 102125 )As you prob know this
> part is only supposed to operate the cold start injector when the
> coolant temperature is below 35oC, after 5 mins of running the switch
> will not be closed due to the higher coolant temperature. BTW the
> switch itself is grounded by the threaded part that goes into the
> water pump, ie not a good idea to seal it in with PTFE tape as this
> may cause this not to work correctly. Use a multimeter at cold and
> then again after 5 mins to confirm the correct operation of this
> switch and save yourself £20 :)
>