Re: [doc] Air con Compressor
[Date Prev][Date Next][Thread Prev][Thread Next][Date Index][Thread Index]
Re: [doc] Air con Compressor
- From: ROBLAMROCK@xxxx
- Date: Wed, 3 Jul 2002 15:33:20 EDT
In a message dated 03/07/02 11:17:16 GMT Daylight Time, paul.salsbury@xxxx writes:
Is the any way I can test the compressor with out the
system being full ( I have no condenser or accumulator
yet)
When should the 'live' feed be going to the
compressor( I presume thats the red wire going into
the to)
As there is no gas I also presume I will need to jump
the pressure cut off by the accumulator too again how?
Paul,
To check if the compressor runs (with or without gas etc) - just disconnect the little bullet junction on the red wire above the compressor and hold a piece of wire from the red jump connector on the right of the engine bay to this connector. The compressor should turn irrespective of other pressure cut off switches.
Robert
Belfast
Back to the Home of PROJECT VIXEN