Re: Cooling problem 2nd question
[Date Prev][Date Next][Thread Prev][Thread Next][Date Index][Thread Index]
Re: Cooling problem 2nd question
- From: jtrealty@xxxx
- Date: Mon, 09 Apr 2001 22:23:22 -0000
It doesn't make any difference how the wires are connected to the
switch. Test the switch. Both terminals should not have any connection
to the case and should have continuity to each other at the preset
temperature. (it should say on the case). Immerse in water and heat
the water and watch the thermometer with a meter connected to the
terminals. Near the prescribed temp the switch should show continuty.
David Teitelbaum
vin 10757
--- In dmcnews@xxxx, paulheymeson@xxxx wrote:
> Hello list,
>
> After trying 3 switches and testing everything else as my last post
> explained.
> I proceded to put my hands on all the pipes to see if they were
> getting hot enough,sure enough they were nearly burning my fingers.
> So I was just wondering as my fans work fine if I join the 2 wires
on
>
Back to the Home of PROJECT VIXEN