Re: [DML] Fans run continuous
[Date Prev][Date Next][Thread Prev][Thread Next][Date Index][Thread Index]

Re: [DML] Fans run continuous



In a message dated 3/11/01 12:37:29 PM Eastern Standard Time, 
tmasterlc@xxxx writes:

<< Our fans used to cycle on and off with engine temp but now run 
continuous from the moment the key is turned on and never shut off. >>

Sounds like the otterstat is bad. To determine this....in the engine 
compartment on the drivers side, u should see 2 wires going to the cooling 
pipes, on the top part of that cooling pipe, you will see a clip that goes 
around it, that is where the otterstat is located, disconnect those wires, 
and see if the cooling fans go off. If they do, then thats your culprit. 
The otterstat is about $20.00, don't forget to replace the seal too while 
your at it.

Later,
Nick
1852
<A HREF="Http://members.aol.com/njp548";>Http://members.aol.com/njp548</A>





Home Back to the Home of PROJECT VIXEN 


Copyright ProjectVixen.com. All rights reserved.

Opinions expressed in posts reflect the views of their respective authors.
DMCForum Mailing List Archive  DMCNews Mailing List Archive  DMC-UK Mailing List Archive

This site contains affiliate links for which we may be compensated