[DML] Re: Vent heat problem
[Date Prev][Date Next][Thread Prev][Thread Next][Date Index][Thread Index]
[DML] Re: Vent heat problem
- From: "DMC Joe" <DMCJOE@xxxx>
- Date: Mon, 9 Aug 1999 11:12:51 -0400
Mike,
Thanks for your suggestion but we installed a new mode switch during our
visit. We have since been in touch with Mr.Howley and belive we have found
the source of his problem.
DMC Joe / DeLorean Services / <dmcjoe@xxxx>
Web Site: <http://www.deloreanservices.com>
----------
> From: magriese@xxxx
> To: dmcnews@xxxxxxxxxxx
> Subject: [DML] Re: Vent heat problem
> Date: Monday, August 09, 1999 9:20 AM
> This sounds like a bad mode switch. The airflow in the ventilation
> system is controlled by vacuum actuators. The actuators are
> controlled by the mode switch in the dash. There is a portion of
> the switch that is sealed with a silicone grease that eventually
> dries out and causes erratic operation of the ventilation system.
>
> Mike Griese
> Storage Software Development Manager
> IBM Storage Systems Division
> Rochester, MN 55901
> Internet: magriese@xxxx
> voice: (507)253-1853
> fax: (507)253-2880