In my particular case, I'm also changing to a 140MPH speedometer and
will require recalibration... Will that process take care of any
changes due to needle weight? Also, do you know if other needles in
the instrument cluster will need recalibration due to new or altered
needles?
Thanks,
--Greg
#2894
--- In dmcnews@xxxxxxxxxxxxxxx, DMCVIN6683 <dmcvin6683@xxxx> wrote:
>
> Just remember do not paint the speedometer needle because it will give
> an inaccurate reading due to the added weight. Our speedometers are
> magnetic driven not gear driven and any added weight to the needle will
> throw off the speedometer.
>