Re: Car will not start ... why ...
- From: jtrealty@xxxx
- Date: Sat, 14 Jul 2001 20:52:28 -0000
Refer to D:04:06 in the workshop manual. The things you should check 
are #31 is a good ground, fuse #1 is good and there is power at #15 on 
run-start (G), fuse #7 is good and there is power to #30 (N) @ all 
times. It could just be that one of the connecters at the relay block 
is not making contact because it slid back. Do not leave the bypass in 
(except for troubleshooting) as you are eliminating a safety control.
David Teitelbaum
vin 10757
--- In dmcnews@xxxx, "Nick Kemp" <nkemp@xxxx> wrote:
> I just replaced the RPM relay thinking the old one went bad and the 
car
> still wont start. The fuel pump does not rev up as per normal when 
the key
> is turned. I tried the RPM relay bypass and it causes the pump to 
rum. I
> even forced the old RPM relay contact closed and the pump runs.
> 
> What are the next things to check for that are keeping the RPM relay 
from
> activating?
> 
> Nick Kemp