-----Original Message----- From: DMC Joe [mailto:dmcjoe@xxxx] Sent: 17 January 2002 06:58 To: dmcnews@xxxxxxxxxxxxxxx Subject: Re: [DML] Instrument light The instrument cluster illumination rheostat has a high failure rate. To temporarily restore your instrument lighting access the under side of the shifter panel and locate the wires leading to the rheostat. You will notice an unused rheostat terminal, unplug one of the wires from the adjoining pair and plug it into the unused terminal. This should restore your instrument illumination to full brightness until you can replace the defective rheostat. DMC Joe DeLorean