Re: [DML] radiator fans / fan fail
[Date Prev][Date Next][Thread Prev][Thread Next][Date Index][Thread Index]

Re: [DML] radiator fans / fan fail



Jim, If things are working properly and all connections are tight, both fans 
will draw about 28 to 30 amps. This depends on how many miles are on the fan 
motors. I took mine apart and rebuilt them, clean, oil, new brushes and they 
now draw about 11-12 amps ea under full load. My new fan fail jumper is now 
fused at 15 amps on ea leg and they just barely heat. That's what you want. I 
try not to over fuse or you loose protection. With 25 amps per leg, you 
might as well wire them direct. 
John Hervey